Sew 863 PR
|
FEATURES
● Two functions in one unit: open phase and phase sequence detection.● Neon light indicators.● Large size alligator clips for easy clipping onto switch- boards terminals.● Allows you to check a wide range of 3-phase power sources.● Special test leads length are available on request.
SPECIFICATIONS
Input voltage
100-500V AC
Frequency range
45 - 70 Hz
Circuit structure
All electronic (not mechanical)
AC power consumption
Approx. 7mA
Dimensions
102(L) × 78(W) × 32.5(D)mm
Weight
Approx. 228g
Safety standard
EN 61010-1 CAT III 500V EN 61326-1
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew 862 PR
|
FEATURES
● Two functions in one unit: open phase and phase sequence detection.● Neon light indicators.● Large size alligator clips for easy clipping onto switch- boards terminals.● Checks a wide range of 3-phase power sources.● Ideal for installing conveyor lines, pump systems and interconnected drivers.● Water proof.● Special test leads length are available on request.
SPECIFICATIONS
Input voltage
100-500V AC
Frequency range
45 - 70 Hz
Circuit structure
All electronic (not mechanical)
AC power consumption
Approx. 7mA
Dimensions
102(L) × 78(W) × 32.5(D)mm
Weight
862 PR : 115g Test leads : 97g Total : Approx. 212g
Safety standard
EN 61010-1 CAT III 500V / CAT IV 300V EN 61326-1
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew 865 PR
|
FEATURES
● The 865 PR is a detector with LEDs to show the de- tection better visible than neon. ● Three functions in one unit, including open phase, phase sequence and 3 phase motor rotation.● Designed for checking a wider range of 3 phase power source from 100V to 500V.● Indicates R.S.T LEDs which frequency range from 40Hz to 400Hz.● Wide range detection of motor frequency range from 2Hz to 400Hz.● Fixed magnets for convenient measurement.
SPECIFICATIONS
Measurement principle
Contact Live Wire
Input voltage
100-500Vac
Frequency range
40Hz-400Hz
Operating temperature & humidity
0°C ~ 40°C Max. 80% R.H.
Storage temperature & humidity
-10°C ~ 50°C Max. 80% R.H.
Cable length
Approx. 1m
Dimensions
128(L) x 72(W) x 44(D)mm
Weight (battery included)
Approx. 220g
Power source
9V (6F22) × 1
Safety standard
EN 61010-1 CAT III 500V EN 61326-1 EN 61557-1 ... |
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew ST-860
|
FEATURES
● Three functions in one unit: open phase, phase sequence and motor rotation indication. ● Large size alligator clips for easy clipping onto switch- boards terminals. ● Highly reliable. ● Identifies 3 phase sequence and open phase check.● Ideal for installing conveyor lines, pump systems and interconnected drivers.
SPECIFICATIONS
Input voltage
100-500V AC
Frequency range
45-70 Hz
Circuit structure
All electronic (not mechanical)
Power requirement
9V (6F22) × 1
Power consumption
Consumption current approx. 14mA of motor rotation field tester
AC power consumption
Approx. 7mA
Dimensions
153(L) × 72(W) × 35(D)mm
Weight (battery included)
Approx. 200g
Safety standard
EN 61010-1 CAT III 500V EN 61326-1
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew 855 PRB
|
FEATURES
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
SPECIFICATIONS
Voltage
200V-600V AC
Frequency response
50 / 60 Hz
Operating temperature & humidity
0°C ~ 40°C at 80% Max. relative humidity
Storage temperature & humidity
-10°C ~ 50°C at 90% Max. relative humidity
Cord
1.1m each of red(R), white(S) and black(T) cord
Dimensions
134(L) × 85(W) × 45(D)mm
Weight
Approx. 530g
Safety standard
EN 61010-1 CAT Ⅳ 600V EN 61010-2-31
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew 855 PRA
|
FEATURES
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
SPECIFICATIONS
Voltage
200V-600V AC
Frequency response
50 / 60 Hz
Operating temperature & humidity
0°C ~ 40°C at 80% Max. relative humidity
Storage temperature & humidity
-10°C ~ 50°C at 90% Max. relative humidity
Cord
1.1m each of red(R), white(S) and black(T) cord
Dimensions
134(L) × 85(W) × 45(D)mm
Weight
Approx. 530g
Safety standard
EN 61010-1 CAT Ⅳ 600V EN 61010-2-31
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew 855 PR
|
FEATURES
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
SPECIFICATIONS
Voltage
200V-600V AC
Frequency response
50 / 60 Hz
Operating temperature & humidity
0°C ~ 40°C at 80% Max. relative humidity
Storage temperature & humidity
-10°C ~ 50°C at 90% Max. relative humidity
Cord
1.1m each of red(R), white(S) and black(T) cord
Dimensions
134(L) × 85(W) × 45(D)mm
Weight
Approx. 530g
Safety standard
EN 61010-1 CAT Ⅳ 600V EN 61010-2-31
|
Phase Sequence Indicators (Contact Type)
|
|
|
|
Sew ST-850
|
FEATURES
● Two functions in one unit: open phase and phase sequence detection.● Lamps let you determine at-a-glance if phase is open.● Large size alligator clips for easy clipping onto switch-boards terminals.● Checks a wide range of 3-phase power sources.● Special test leads length are available on request.● Push button switch is designed to minimize damage due to negligence.
SPECIFICATIONS
Voltage
90V-600V AC
Frequency response
50 / 60 Hz
Operating temperature & humidity
0°C ~ 40°C at 80% Max. relative humidity
Storage temperature & humidity
-10°C ~ 50°C at 90% Max. relative humidity
Cord
1.1m each of red(R), white(S) and black(T) cord
Dimensions
134(L) × 85(W) × 45(D)mm
Weight
Approx. 510g
Safety standard
IEC 1010 CAT II 600V
|