Megger OTS60SX Semi-Automatic 60 kV Oil Test Set
|
Lightweight portable unit for field use
Simple, semi-automatic operation
Suitable for all oil breakdown testing to 60 kV
Automatic 1 minute timer for easy withstand testing
|
Megger
|
|
|
|
Megger PAT320 Portable Appliance Tester
|
Simple manual or automatic operation
120 V 60 Hz operation
User-selectable PASS/FAIL limits
Fast test times selectable from 1s
Ground bond testing at 25 A, 10 A and 200 mA
Differential, touch and substitute ground leakage testing
|
Megger
|
|
|
|
Megger TDR500 Hand-Held Time Domain Reflectometer/Cable Fault Locater
|
Simple Operation
Warble Tone Generator
Velocity factor from 0.30 to 0.99
Range to 10,000 ft (3 km)
Tough ABS case
IP54 environmental protection
Carry case and test leads included
|
Megger
|
|
|
|
Megger TDR500/3 Handheld Time Domain Reflectometer
|
Backlit graphics monochrome LCD (256 x 128)
Adjustable display contrast
Resolution to 0.1 m
For use on Telecom TNV-3 circuit, or 150V CAT IV power circuits
Power blocking filter not required
Environmental protection to IP54
2ns pulse for near end fault location
AUTO option selecting gain and pulse for each range
Display distance in metres or feet
Uses five AA (LR6) primary cells
|
Megger
|
|
|
|
Megger TDR900 Hand-Held Time Domain Reflectometer/ Cable Length Meter
|
Full autoranging for measuring the lenght of power, telphony, CATV, and LAN cables, provides distance to an open or short.
Extra large, high resolution backlit LCD.
Automatic output impedance control of 25, 50, 75, 100, 125, or 150 ohms.
User-friendly menu on screen operation.
Cable length calibration function.
Internal library of 39 standard cable types
|
Megger
|
|
|
|
Megger TPT220 AC/DC Voltage Tester
|
AC and DC voltage from 6 to 1000 V
Resistance / Continuity (acoustically) 0 to 2 kΩ
RCD function test
Two pole phase sequence indication
LCD display
CAT IV 1000 V rating
Exhausted battery warning indicator
Auto power off
|
Megger
|
|
|
|
Megger TTR20 Transformer Turns Ratio Tester
|
Single- and three-phase transformer testing
Fast, easy hand-held operation.
Powered by six standard “AA” alkaline batteries; no charger needed.
Provides up to 12 hours of field operation.
Measures turns ratio range of 10,000:1, with a high accuracy (±0.1%, 0.8 to 2000) at a low excitation voltage
Records ratio errors for bushing CTs to an accuracy of±0.1% nameplate. This reduces the need for additional test equipment and improves set-up time.
Perfect for meter shops, the TTR20 can be used for inspection purposes to determine the no-load accuracy of most CTs and PTs. It also can be used to determine the need to test potentially faulty CTs and PTs.
Automatic self-calibration for each test.
Simple, one-button operation Quick-start guide on front panel
|
Megger
|
|
|
|
Motor101A Data Logging System
|
The Motor101A measures and records on and off status changes for motors or other equipment drawing up to 200 Amps. The state change occurs when the current switch exceeds the 150mA set point. This allows for most basic equipment to be monitored.
The current switch monitors whether there is current passing through a wire around which it is clamped. When the current exceeds 150mA’s, the output changes and provides a voltage for the Motor101A to measure. The device can hold up to 406,323 state changes, but memory will only be used if the status has changed. The device can be programmed to check for status changes 4 times per second up to once every 24 hours.
The Motor101A-NC includes the data logger and current switch. The Motor101A-C includes a data logger, current switch and an IFC200 interface cable. |
Data Logger Systems
|
|